Termomeccanica – Terceira, Portugal
Power plant from "waste".
- Type
- Electricity from waste
- Fuel
- RSU - 5 t/h - 43.200 t/yr
- Boiler data
- 15,1 t/h, 43 bar, 400°C (SH)
- Furnace Thermal Power
- 11,1 MWth
- Electric power
- 2,5 MWe
- Scope
- Water-tube boiler integrated on the grate furnace